Zero Transfer Time UPS - ICONICA 5kW 48V Inverter-Charger and 4x Rolls 3.12kWh 12V AGM Batteries

  

Delivery available

Zero Transfer Time UPS – ICONICA 5kW 48V Inverter-Charger with 4 × Rolls S12-290AGM 3.12kWh Batteries

  • Keep selected equipment powered during a mains outage, with 0ms transfer between line and battery modes when correctly configured.
  • Supply up to 5,000W of continuous pure sine wave power from a 48V AGM battery bank.
  • Four Rolls batteries provide 12.48kWh nominal storage at C20, with mains charging and an integrated MPPT solar charge controller.

5kW zero transfer time UPS for essential business loads

This zero transfer time UPS combines an ICONICA IC-ZT5000-48 inverter-charger with four Rolls S12-290AGM 260Ah (C20) deep-cycle batteries. Connected in series, the batteries form a 48V, 12.48kWh battery bank for selected essential-load circuits. The inverter accepts mains or a compatible generator supply and can also charge from a correctly designed solar array.

This inverter has the ability to be connected in parallel with additional identical units (maximum of 8 further inverters), offering the possibility of large-scale system expansion, with up to 45kW of power handling capability and up to 112.3kWh battery storage capacity. Once connected in parallel, there is the option for 3-phase operation (ideal if the system is being used to power industrial grade equipment and machinery run on 3 phase). Each inverter connected in the system will require a parallel connection kit (sold separately).

Key features

  • Continuity for sensitive equipment: 0ms transfer between line and battery modes. Transfer between inverter and bypass modes is 4ms, so operating-mode configuration matters.
  • 5kW pure sine wave output: 5kVA/5kW continuous inverter rating, with twice rated power available for five seconds within the inverter’s operating limits.
  • Deep-cycle AGM storage: four 12V batteries, each rated at 260Ah at C20, provide a 4 x 3.12kWh 48V series bank without routine electrolyte topping-up.
  • Flexible charging: up to 60A mains charging and an integrated 80A MPPT controller supporting up to 4,000W of compatible solar input.
  • Local control and monitoring: removable LCD display, Bluetooth and RS232 communication, with overload, overtemperature and short-circuit protection.

Where to use

Suitable for assessed essential-load circuits serving logistics offices, commercial workstations, network switches, routers, CCTV recorders, access-control equipment and selected small-server installations. Check total running power, starting surges, equipment compatibility and required backup duration before specifying the system.

This package provides a single-phase supply for selected loads, not a complete factory or warehouse backup system. Medical, life-safety and other specialist applications require a separate suitability assessment.

System contents and usable capacity

  • 1 × ICONICA IC-ZT5000-48 5kW 48V zero transfer time inverter-charger.
  • 4 × Rolls S12-290AGM 12V deep-cycle AGM batteries, each with 3.12kWh nominal energy at C20.
  • 1 x Mersen DC Fused Disconnect 2-pole NH1 fuse size 250ADC max
  • Required cables, battery interlinks, fuses, AC protection and any enclosure included.

The bank’s 12.48kWh figure is nominal stored energy at the 20-hour discharge rate, not guaranteed usable AC energy. A 50% depth-of-discharge allowance corresponds to 6.24kWh of that nominal figure before inverter losses and discharge-rate effects. Actual runtime depends on load, battery temperature, condition and commissioned cut-off settings.

Installation and commissioning

This is not a plug-in UPS. A qualified electrician must design and install the battery connections, DC protection and isolation, AC protection, earthing and essential-load circuits. Ask Energian about installation through trusted partners.

Install the inverter vertically on a suitable non-combustible surface. Provide a secure, ventilated battery location with sufficient access and structural support: the four batteries weigh 312kg before cables or an enclosure are added.

Set charging voltage, charging-current limits and low-voltage protection for the Rolls batteries and their operating temperature. Do not assume the inverter’s default AGM profile is suitable. Keep battery equalisation disabled and confirm the maximum permitted charging current before enabling simultaneous solar and mains charging.

Technical specifications

Inverter figures use the 5kW column of the supplied IC-ZT user manual, version 1.2. Battery figures follow the supplied S12-290 AGM datasheet. Calculated system figures are identified separately.

Specification Value
System configuration
Inverter model ICONICA IC-ZT5000-48
Battery quantity and model 4 × Rolls S12-290AGM
Battery-bank arrangement Four 12V batteries in series; one 48V string
Bank capacity at C20 260Ah at 48V
Bank capacity at C100 290Ah at 48V
Bank capacity at C10 234Ah at 48V
Nominal energy per battery at C20 — calculated 3.12kWh: 12V × 260Ah
Nominal bank energy at C20 — calculated 12.48kWh: 48V × 260Ah
Nominal bank energy at C100 — calculated 13.92kWh: 48V × 290Ah
Nominal bank energy at C10 — calculated 11.232kWh: 48V × 234Ah
50% of C20 nominal bank energy — calculated 6.24kWh before inverter losses and discharge-rate effects; not a guaranteed usable-energy rating
Battery weight  78kg
Combined inverter and battery net weight — calculated 325.5kg, excluding cables, protection devices, enclosure and packaging
Inverter: AC input and line mode
Input waveform Sinusoidal
Nominal AC input voltage 230V AC
Maximum AC input voltage 300V AC
Low-loss input voltage / return voltage 110V AC ±7V / 120V AC ±7V
High-loss input voltage / return voltage 280V AC ±7V / 270V AC ±7V
Nominal input frequency 50Hz / 60Hz, automatic detection
Low-loss frequency 46Hz at 50Hz input;  ±1Hz
Low-loss return frequency 46.5Hz at 50Hz input; 
High-loss frequency 54Hz at 50Hz input;  ±1Hz
High-loss return frequency 53Hz at 50Hz input;  ±1Hz
Power factor >0.98
Peak line-mode efficiency 93%
Transfer time: line ↔ battery 0ms
Transfer time: inverter ↔ bypass 4ms
Output short-circuit protection Circuit breaker in line mode; electronic circuits in battery mode
Inverter: battery mode and AC output
Rated output 5kVA / 5kW
Output waveform Pure sine wave
Output voltage regulation 230V AC ±5%
Output frequency 50Hz or 60Hz
Peak battery-mode efficiency 90%
Overload protection 5 seconds at ≥150% load; 10 seconds at 105–150% load
Surge capacity Twice rated power for 5 seconds
Nominal DC input voltage 48V DC
DC operating range 40–66V DC
Cold-start voltage 46V DC
Low DC warning voltage 45V at <50% load; 44V at ≥50% load
Low DC warning return voltage 47V at <50% load; 46V at ≥50% load
Low DC cut-off voltage in specification table 43V at <50% load; 42V at ≥50% load
User-defined low DC cut-off setting 40.0–54.0V in 0.1V increments; must be commissioned for the batteries
High DC recovery / cut-off voltage 64V / 66V
No-load power consumption <75W
Inverter: mains and solar charging
Mains charging current at nominal AC voltage 30A default; 60A maximum
Mains charging-current selections 2A, 10A, 20A, 30A, 40A, 50A or 60A, subject to the total charging-current setting
Charging algorithm Three-stage: bulk, absorption and float
Default AGM/GEL bulk voltage 56.4V DC; inverter preset, not the commissioned Rolls battery setting
Default flooded-battery bulk voltage 58.4V DC; not the battery-type selection for this AGM package
Default float voltage 54V DC; inverter preset, not the commissioned Rolls battery setting
User-defined bulk and float voltage ranges 48.0–64.0V in 0.1V increments
Overcharge protection 66V DC
Solar charge-controller type MPPT
Maximum solar input power 4,000W
Maximum solar charging current 80A
Maximum solar-controller efficiency 98.0%
Maximum PV array open-circuit voltage 145V DC; array design must account for cold-weather voltage rise
PV MPPT operating range 60–115V DC
Battery-voltage measurement accuracy ±0.3%
PV-voltage measurement accuracy ±2V
Maximum combined mains and solar charging current 140A inverter capability; this is not an approved charging-current setting for the supplied battery bank
Total charging-current adjustment 10–140A in 10A increments; 60A default
Inverter: ECO/bypass mode
Input waveform Sinusoidal
Low-loss input voltage / return voltage 176V AC ±7V / 186V AC ±7V
High-loss input voltage / return voltage 280V AC ±7V / 270V AC ±7V
Nominal input frequency 50Hz / 60Hz, automatic detection
Low-loss frequency / return frequency 46Hz / 46.5Hz at 50Hz input; ±1Hz
High-loss frequency / return frequency 54Hz / 53Hz at 50Hz input; ±1Hz
Inverter: controls and environment
Display Removable LCD display with status indicators and function buttons; remote mounting requires an optional communication cable
Communication RS232 and Bluetooth; USB functions for firmware, parameter transfer and data logs
Bluetooth monitoring WatchPower; manual states approximately 6–7m range in open space
Dry contact 3A / 250V AC for external signalling
Operating modes Automatic, online and ECO options; configurable utility-first, solar-first and solar/battery/utility priorities
Operating temperature 0°C to 55°C
Storage temperature −15°C to 60°C
Relative humidity 5–95%, non-condensing
Inverter dimensions, D × W × H 140 × 303 × 525mm
Inverter net weight 13.5kg
Rolls S12-290AGM: per-battery specifications
Battery technology Deep-cycle AGM lead-acid
Nominal voltage 12V
Capacity at C100, 25°C 290Ah
Capacity at C20, 25°C 260Ah
Capacity at C10, 25°C 234Ah
Internal resistance 1.8mΩ, fully charged at 25°C
Maximum short-duration discharge 2,600A for 5 seconds at 25°C; not a continuous operating rating
Standard terminal LT
Terminal hole shown in drawing Ø9mm
Battery dimensions, L × W × H 521 × 269 × 245mm
Weight per battery 78kg
Cycle charging voltage at 25°C 14.5–14.9V DC per battery
Float charging voltage at 25°C 13.6–13.8V DC per battery
Four-battery cycle-voltage range — calculated 58.0–59.6V DC at 25°C; final setting to follow Rolls commissioning guidance
Four-battery float-voltage range — calculated 54.4–55.2V DC at 25°C; final setting to follow Rolls commissioning guidance
Capacity at 40°C / 25°C / 0°C / −15°C 102% / 100% / 85% / 65%, based on the 20-hour rate
Capacity remaining after storage at 25°C 91% after 3 months; 82% after 6 months; 64% after 12 months
Reserve capacity at 25A 530 minutes
Reserve capacity at 75A 130 minutes
Cold-cranking rating at 0°C 1,830A, as labelled in the datasheet; not an inverter continuous-discharge rating
Cold-cranking rating at −18°C 1,525A; not an inverter continuous-discharge rating
Battery constant-current discharge data
Discharge-test endpoint 1.75V per cell: 10.5V per battery, or 42V for the four-battery series string. This is a test endpoint, not a recommended routine operating target.
30-minute discharge current 233A
45-minute discharge current 172A
1-hour discharge current 147.8A
2-hour discharge current 78.3A
3-hour discharge current 58.9A
5-hour discharge current 41.3A
8-hour discharge current 28.3A
10-hour discharge current 23.40A
20-hour discharge current 13.00A
Discharge-data interpretation Battery test figures, not guaranteed system runtimes. The same current flows through all batteries in series; constant-power inverter current increases as bank voltage falls.
Installation and battery-care requirements
Battery-bank sizing reference The inverter manual suggests at least 200Ah for the 5kW model; this package provides 260Ah at C20.
Battery enclosure Secure, accessible and ventilated; do not install the AGM bank in a completely sealed enclosure
Battery spacing Rolls recommends 25–75mm between batteries for airflow and maintenance access.
Charging configuration Verify current limits, absorption duration and temperature-adjusted voltage settings against Rolls guidance and the battery labels.
Equalisation Disabled for AGM batteries
Protection and isolation External battery overcurrent protection, suitable isolation, AC protection and earthing must be designed for the installation.
Maintenance safety Isolate all relevant AC, battery and PV supplies before work. The inverter’s on/off switch alone does not provide safe isolation.